TORAY RO MEMBRANE
Seawater desalination
Series |
Membrane Element Model |
Size (in.) |
Desalination Rate (%) / Boron Rejection Rate (%) |
Water Production (gpd) (m³/d) |
Effective Membrane Area (ft²) (m²) |
Channel Width (mil) |
TM |
TM810V |
4 |
99.80/92 |
1900(7.2) |
87(8) |
34 |
TM820V-400 |
8 |
99.80/92 |
9000(34.1) |
400(37) |
34 |
TM820V-440 |
8 |
99.80/92 |
9900(37.5) |
440(41) |
28 |
TM820M-400 |
8 |
99.80/95 |
7000(26.5) |
400(37) |
34 |
TM820M-440 |
8 |
99.80/95 |
7700(29.2) |
440(41) |
28 |
TM820K-400 |
8 |
99.86/96 |
5800(21.9) |
400(37) |
34 |
TM820K-440 |
8 |
99.86/96 |
6400(24.2) |
440(41) |
28 |
TM810V |
4 |
99.80/92 |
1900(7.2) |
87(8) |
34 |
TM820V-400 |
8 |
99.80/92 |
9000(34.1) |
400(37) |
28 |
TSW |
TSW-400LE |
8 |
99.8/90 |
12100(45.8) |
400(37) |
34 |
TSW-440LE |
8 |
99.8/90 |
13000(49.2) |
440(41) |
28 |
Test Conditions*1 |
Operating pressure 800 psi (5.52 Mpa) |
Test solution temperature 77ºF(25ºC) |
Test solution concentration32000 mg/L (as NaCl) |
Boron content: 5 mg/L (pH 8) |
Recovery rate of a single membrane element8% |
pH of the test solution7 |
Brackish water desalination
Series |
Membrane Element Model |
Size (in.) |
Desalination Rate (%) / Boron Rejection Rate (%) |
Water Production (gpd) (m³/d) |
Effective Membrane Area (ft²) (m²) |
Channel Width (mil) |
TM |
TM710D*1 |
4 |
99.80 |
2600(9.8) |
87(8) |
34 |
TM720D-400*1 |
8 |
99.80 |
11000(41.6) |
400(37) |
34 |
TM720D-440*1 |
8 |
99.80 |
12100(45.7) |
440(41) |
28 |
TMG |
TMG10D*2 |
4 |
99.7 |
2650(10.0) |
87(8) |
34 |
TMG20D-400*2 |
8 |
99.7 |
12100(45.8) |
400(37) |
34 |
TMG20D-440*2 |
8 |
99.7 |
13300(50.3) |
440(41) |
28 |
TBW |
TBW-400HR*3 |
8 |
99.8 |
6900(26) |
400(37) |
34 |
TBW-440HR*3 |
8 |
99.8 |
7900(30) |
440(41) |
28 |
TMH |
TMH10A*4 |
4 |
99.3 |
2400(9.1) |
87(8) |
34 |
TMH20A-400C*4 |
8 |
99.3 |
11000(41.6) |
400(37) |
34 |
TMH20A-440C*4 |
8 |
99.3 |
12100(45.7) |
440(41) |
28 |
Test Conditions*1 |
Operating pressure 225psi(1.55MPa) |
Test solution temperature 77ºF(25ºC) |
Test solution concentration2000mg/L(as NaCl) |
Recovery rate of a single membrane element15% |
pH of the test solution7 |
Test Conditions*2 |
Operating pressure 150psi(1.03MPa) |
Test solution temperature77ºF(25ºC) |
Test solution concentration2000mg/L(as NaCl) |
Recovery rate of a single membrane element15% |
pH of the test solution7 |
Test Conditions*3 |
Operating pressure110psi(0.76MPa) |
Test solution temperature 77ºF(25ºC) |
Test solution concentration500mg/L(as NaCl) |
Recovery rate of a single membrane element15% |
pH of the test solution7 |
Test Conditions*4 |
Operating pressure100psi(0.69MPa) |
Test solution temperature77ºF(25ºC) |
Test solution concentration500mg/L(as NaCl) |
Recovery rate of a single membrane element15% |
pH of the test solution7 |
Sewage reuse
Series |
Membrane Element Model |
Size (in.) |
Desalination Rate (%) / Boron Rejection Rate (%) |
Water Production (gpd) (m³/d) |
Effective Membrane Area (ft²) (m²) |
Channel Width (mil) |
TML |
TML10D*1 |
4 |
99.8 |
1900(7.2) |
73(7) |
34 |
TML20D-400*1 |
8 |
99.8 |
10500(39.7) |
400(37) |
34 |
TLF |
TLF-400DG*2 |
8 |
99.5 |
11500(43.5) |
400(37) |
34 |
TLF-400HD*1 |
8 |
99.8 |
10500(39.7) |
400(37) |
34 |
|
|
|
|
|
|
|
Test Conditions*1 |
Operating pressure225psi(1.55MPa) |
Test solution temperature77ºF(25ºC) |
Test solution concentration2000mg/L(as NaCl) |
Recovery rate of a single membrane element15% |
pH of the test solution7 |
Test Conditions*2 |
Operating pressure150psi(1.03MPa) |
Test solution temperature77ºF(25ºC) |
Test solution concentration2000mg/L(as NaCl) |
Recovery rate of a single membrane element15% |
pH of the test solution7 |
Ultra - pure water preparation
Series |
Membrane Element Model |
Size (in.) |
Desalination Rate (%) / Boron Rejection Rate (%) |
Water Production (gpd) (m³/d) |
Effective Membrane Area (ft²) (m²) |
Channel Width (mil) |
TBW |
TBW-400HR*2 |
8 |
99.8 |
6900(26) |
400(37) |
34 |
TBW-440HR*2 |
8 |
99.8 |
7900(30) |
440(41) |
28 |
TMG |
TMG20D-400*1 |
8 |
99.7 |
12100(45.8) |
400(37) |
34 |
TMG20D-440*1 |
8 |
99.7 |
13300(50.3) |
440(41) |
28 |
Test Conditions*1 |
Operating pressure150psi(1.03MPa) |
Test solution temperature77ºF(25ºC) |
Test solution concentration2000mg/L(as NaCl) |
Recovery rate of a single membrane element15% |
pH of the test solution7 |
Test Conditions*2 |
Operating pressure110psi(0.76MPa) |
Test solution temperature77ºF(25ºC) |
Test solution concentration500mg/L(as NaCl) |
Recovery rate of a single membrane element15% |
pH of the test solution7 |
Zero - discharge of high - salinity water
Series |
Membrane Element Model |
Size (in.) |
Desalination Rate (%) / Boron Rejection Rate (%) |
Water Production (gpd) (m³/d) |
Effective Membrane Area (ft²) (m²) |
Channel Width (mil) |
TZD |
TZD-LF*1 |
8 |
99.8 |
10500(39.7) |
400(37) |
34 |
TZD-LP*2 |
8 |
99.7 |
6500(24.6) |
370(34) |
37 |
TZD-HR*2 |
8 |
99.8 |
9000(34.1) |
400(37) |
34 |
TZD-HF*2 |
8 |
99.7 |
9900(37.5) |
440(41) |
30 |
TZD-HP*2 |
8 |
99.7 |
7400(28.0) |
370(34) |
37 |
TZD-NF*3 |
8 |
99.0 |
9000(34.1) |
400()37) |
32 |
Test Conditions*1 |
Operating pressure225psi(1.55MPa) |
Test solution temperature77ºF(25ºC) |
Test solution concentration2000mg/L(as NaCl) |
Recovery rate of a single membrane element15% |
pH of the test solution7 |
Test Conditions*2 |
Operating pressure800psi(5.52MPa) |
Test solution temperature77ºF(25ºC) |
Test solution concentration32000mg/L(as NaCl) |
Recovery rate of a single membrane element8% |
pH of the test solution7 |
Test Conditions*3 |
Operating pressure75psi(0.52MPa) |
Test solution temperature77ºF(25ºC) |
Test solution concentration2000mg/L(as NaCl/MgSO4) |
Recovery rate of a single membrane element15% |
pH of the test solution6.5-7.0 |
Special applications
Series |
Membrane Element Model |
Size (in.) |
Desalination Rate (%) / Boron Rejection Rate (%) |
Water Production (gpd) (m³/d) |
Effective Membrane Area (ft²) (m²) |
Channel Width (mil) |
SU |
SU-710T*1 |
4 |
99.4 |
1700(6.5) |
73(7) |
37 |
SU-720TS*2 |
8 |
99.4 |
6900(26.0) |
366(34) |
34 |
SUL |
SUL-G10TS*3 |
4 |
99.5 |
1300(5.0) |
73(7) |
37 |
SUL-G20TS*4 |
8 |
99.5 |
7900(30.0) |
366(34) |
34 |
SUL-G20FTS*4 |
8 |
99.5 |
9500(36.0) |
409(38) |
28 |
TMRO |
TMRO 4040HS*5 |
4 |
99.5 |
1975(7.5) |
85(7.9) |
28 |
TMRO 8040HS*5 |
8 |
99.5 |
9000(34.1) |
400(37.2) |
28 |
TMRO 4040HSX*5 |
4 |
99.5 |
1975(7.5) |
85(7.9) |
28 |
TMRO 8040HSX*5 |
8 |
99.5 |
9000(34.1) |
400(37.2) |
28 |
Test Conditions*1 |
Operating pressure220psi(1.5MPa) |
Test solution temperature77ºF(25ºC) |
Test solution concentration1500mg/L(as NaCl) |
Saltwater flow rate20L/min(5.3gpm) |
pH of the test solution6.5 |
Test Conditions*2 |
Operating pressure220psi(1.5MPa) |
Test solution temperature77ºF(25ºC) |
Test solution concentration1500mg/L(as NaCl) |
Saltwater flow rate80L/min(21.1gpm) |
pH of the test solution6.5 |
Test Conditions*3 |
Operating pressure110psi(0.75MPa) |
Test solution temperature77ºF(25ºC) |
Test solution concentration500mg/L(as NaCl) |
Saltwater flow rate20L/min(5.3gpm) |
pH of the test solution6.5 |
Test Conditions*4 |
Operating pressure110psi(0.75MPa) |
Test solution temperature77ºF(25ºC) |
Test solution concentration500mg/L(as NaCl) |
Saltwater flow rate80L/min(21.1gpm) |
pH of the test solution6.5 |
Test Conditions*5 |
Operating pressure150psi(1.03MPa) |
Test solution temperature77ºF(25ºC) |
Test solution concentration2000mg/L(as NaCl) |
Recovery rate of a single membrane element15% |
pH of the test solution7 |

Applications:
- Water purification
- Reclaim water reuse
- Seawater desalination field
- Papermaking water treatment
FILMTECTM membrane elements come in different models, each for different applications and conditions of use:
1. NF270 - Medium-sized desalination rate and hardness transmission rate of nanofiltration membrane, high removal of organic matter, high water production
2, NF200 - medium hardness membrane permeability of nanofiltration, with high herbicide (such as deuterated net) and TOC removal rate
3, NF90 - 90% salt removal rate of nanofiltration membrane, with high iron, insecticides, herbicides and TOC removal rate
4, NF - process material concentration with nanofiltration membrane
5, XLE - very low energy consumption (pressure) reverse osmosis components, mainly used for commercial or large municipal water treatment
6, LP - tape wound ultra-low pressure reverse osmosis element, a new generation of high desalination rate of commercial ultra-low pressure reverse osmosis membrane elements
7, BW30HRLE - a new type of fiberglass winding high salt rejection of low energy brackish water reverse osmosis element
8, TW30 - Tape winding standard low pressure reverse osmosis membrane component, mainly used for high desalination rate of tap water into commercial reverse osmosis system
9, BW30 - FRP winding standard low pressure brackish water reverse osmosis membrane components, mainly used for multiple series high desalination rate reverse osmosis system
10, BW30LE - standard low energy brackish water reverse osmosis element
11, LE - new low-energy brackish water reverse osmosis element
12. RO - Health Grade Reverse Osmosis Element
13, HSRO - Thermal disinfection of sanitary reverse osmosis elements
14, SG30 - Semiconductor grade reverse osmosis element for ultrapure water
15. SG30LE - Semiconductor Grade Reverse Osmosis Element for Low Energy Ultrapure Water
16, SW30 - seawater and high salinity brackish water (subtropical water) reverse osmosis elements
17, SW30XLE - a new type of very low energy seawater or high salinity brackish water (subsea water) reverse osmosis element
18, SW30HR - standard high desalination rate (single stage seawater desalination) seawater reverse osmosis element
19, SW30HRLE - a new type of high desalination rate and low energy consumption (single stage seawater desalination) seawater reverse osmosis element


FAQ
1. Q: When can I get the quotation?
We usually quote within 24 hours after we get your inquiry.If you are very urgent to get the price, please call us or tell us from your email,so that we will regard your inquiry priority.
2. Q: Do you Accept OEM service?
A: Yes! we can manufacture according to your requirement.
3. Q: What kinds of filter do you produce?
A: High flow filter cartridge, wire water filter, pleated filter cartridge, security filter equipment, RO Membrane Element and RO Equipment, and so on. You can turn to us for any kinds of filters and filter related parts.
4. Q: How do you pack products?
A: Standard exporting carton, wooden, pallet, customized.
5. Q: how long it your lead time?
A: Air shipment orders can be ready in 5 working days, sea shipment orders can be ready in 10 working days.
6. Q: What is your terms of delivery?
A: We accept EXW, FOB, CIF, etc. You can choose the one which is the most convenient or cost effective for you.
7:Q: How should I place an order?
A:Please kindly click" send inquiry" or "contact supplier", Then our sales engineer will recommend you suitable products for your selection also give some valuable suggestion for your selection.